| Parameters & Calibration range | |||||
| Must | Brix: 12 - 27 °Brix pH: 2.6 - 4.0 Volatile Acid: 0 - 0.6 g/l TA to pH 7.0: 2 - 12 g/l Alpha Amino Nitrogen: 17 - 345 mg/l | Ammonia: 0 - 175 mg/l Density: 1.04 - 1.15 g/ml Gluconic Acid: 0.03 - 4.63 g/l Malic Acid: 0.1 - 7.26 g/l Tartaric Acid: 0 - 11.7 g/l | |||
| Must under fermentation | Glu+Fru: 0 - 240 g/l pH: 2.6 - 4.0 TA to pH 7.0: 2.0 - 6.5 g/l Malic Acid: 0 - 7 g/l Volatile Acid: 0 - 0.6 g/l Ethanol: 0 - 13 Vol % | ||||
| Finished wine | Glu+Fru: 0 - 20 g/l pH: 2.6 - 4.0 TA to pH 7.0: 2 - 5 g/l Malic Acid: 0 - 6 g/l Volatile Acid: 0 - 1.0 g/l Ethanol: 8 - 16 Vol % Density: 0.99 - 1.01 g/ml | Lactic Acid: 0 - 4.63 g/l Glucose: 0.02 - 10.65 g/l Fructose: 0.15 - 10.20 g/l | |||
| Sweet wine | Ethanol: 7-19 Vol % Glucose + Fructose: 0 - 180 g/l Malic Acid: 0 - 5.2 g/l Total Acidity: 0.2 - 6.0 g/l Volatile Acidity: 0 - 1.2 g/l pH: 2.9 - 4.0 | ||||
| Colour | Colour abs 420: 0 - 1.2 | ||||
| Accuracy | See application notes for performance details | ||||
| Repeatability | See application notes for performance details | ||||
| Analysis time | FTIR wine unit; 2 minutes | ||||
| Sample ambient temperature | 10°C - 35°C | ||||
| Sample volume | 600 µl of must, must under fermentation or finished wine with a manual pipette. Close the lid and start analysis within 6 seconds to ensure reliable results | ||||
| Instrument warm up time | 1 hour | ||||
| Cleaning | With a regular tissue and commonly used detergent cleaning liquids | ||||
| Sample preparation | Clarify sample using a centrifuge or filtration. Particle size <10 µm.="" in="" case="" of="" excess="" co2,="" degassing="" is="" necessary="" (e.g.="" use="" vacuum="" pump,="" ultrasonic="" treatment="" or="" shake="">10> | ||||
| Calibration routines | Slope & Intercept Adjustment | ||||
| SW package | Foss Integrator with PLS calibrations | ||||
| FTIR calibrator | Build your own calibrations with the FTIR Calibrator software | ||||
| Cuvette FTIR wine unit | Cuvette with variable light pathways | ||||
| Cuvette VIS colour unit | 2 mm (700 µl) | ||||
| Installation requirements | |||||
| Power Supply | 100 - 240 VAC ± 10%, 50 - 60 Hz | ||||
| Power consumption | 66 VA [max of Power supply] | ||||
| Ambient temperature | 10°C - 35°C | ||||
| Ambient humidity | < 93%=""> | ||||
| Weight | Wine unit: 6,3 kg. Colour unit: 3,8 kg | ||||
| Dimensions (H×W×D) | 189 × 154 × 321 mm (excl PC), same size for each module | ||||
| Environment | Place the instrument on a stable surface away from excessive and continuous vibration. Do not place the instrument in direct sunlight or close to an open window. | ||||
| Degree of ingress protection | IP40 | ||||
| Noise level | < 70="" db="" (measured="" value="" typically="" lower="" than="" 45=""> | ||||
| Altitude | < 2000=""> | ||||
| |
Switzerland Matthias Schulz |
| https://carlex-ag.com/web/CH/ |
|
Matthias Schulz
CARLEX Export Switzerland GmbH, Suurstoffi 37 , 6343 Rotkreuz
Mob.: +41 78 774 6337
E-mail: matthias.schulz@carlex-export.ch
| |
Ukraine Alex Filonenko |
| https://altima.plus/ |
|
Office 15, 58-A Holosiivskyi Avenue, Kyiv, 03039, Ukraine
Tel.: +380 44 4943015, +380 44 4943005
E-mail: info@altima.plus
Mrs. Victoria Berezovska
Office Co-ordinator
mob. tel.: +380 50 351 3631
E-mail: victoria@altima.plus
Alex Filonenko
Director
mob. tel: +380 67 236 5094
E-mail: alex@altima.plus
Mr. Nick Shkil
Service Engineer
mob. tel: +380 67 233 4339
E-mail: nick@altima.plus
| |
Moldova Carmen Iacob |
| https://carlex-ag.com/web/RO/ |
|
SERVITECH EXPRES SRL
Str. Eftimie Murgu nr. 2, Bl. D1, Sc. B, Ap. 7
500271 Brasov
Romania
Phone: +40368463992
Mobile: +40744859805
E-mail: servitech@servitechexpres.ro
SERVITECH EXPRES SRL
Carmen Iacob
Mobile: +40744859805
E-mail: carmen.iacob@servitechexpres.ro
TM INOX SOLUTION SRL
Igor Borsci
Mobile: +37360187907
E-mail: igor@tminox.md
SERVITECH EXPRES SRL
Florin Badea
Mobile: +40740055477
E-mail: florin.badea@servitechexpres.ro
| |
Kazahkstan Alex Romaniko |
| http://carlex.kz/ |
|
г. Астана, Казахстан, 010000
Коргальджинское шоссе 19, офис 204
Tel: +7 (7172) 999-159
Tel: +7 (7172) 573-973
Mob: +7 (702) 6185810
Olga.Romaniko@carlex.kz
Alex Romaniko
г. Астана, Казахстан, 010000
Коргальджинское шоссе 19, офис 204
Tel: +7 (7172) 999-159
Tel: +7 (7172) 573-973
Mob: +7 (702) 6185810
e-mail: Alex.Romaniko@carlex.kz
Alex Bolgarov
г. Астана, Казахстан, 010000
Коргальджинское шоссе 19, офис 204
e-mail: Alex.Bolgarov@carlex.kz
| |
Georgia Agrotest Ltd |
| https://carlex-ag.com/web/GE/ |
|
35, D. Agmashenebeli str. Village Digomi.
0126 Tbilisi
Georgia.
Tel: +995 322 144 848
+995 322 515 275
| |
Armenia Alex Filonenko |
| https://carlex-ag.com/web/AM/ |
|
Alex Filonenko
Director, Carlex Export AG, Ukraine, MBA
Tel: +380 44 494 30 15
Mob.: +380 67 236 50 94
Web: altima.plus
E-mail: alex@altima.plus
| |
Azerbaijan Mr. Bahram Atabeyli |
| http://caucasusconsulting.org/ |
|
Mr. Bahram Atabeyli
Country Manager, Carlex Export AG, Azerbaijan
CAUCASUS CONSULTING GROUP OF COMPANY
LUXEN PLAZA
Khatai St. 34
AZ1008 Baku, Azerbaijan
Phone: +994124962316
Mobile: +994502554500
email:
ata@carlex-ag.com
WEB:
| |
Kyrgyzstan Alex Filonenko |
| https://carlex-ag.com/web/KG/ |
|
Alex Filonenko
Director, Carlex Export AG, Ukraine, MBA
Tel: +380 44 494 30 15
Mob.: +380 67 236 50 94
Web: altima.plus
E-mail: alex@altima.plus
| |
Tajikistan Alex Filonenko |
| https://carlex-ag.com/web/TJ/ |
|
Alex Filonenko
Director, Carlex Export AG, Ukraine, MBA
Tel: +380 44 494 30 15
Mob.: +380 67 236 50 94
Web: altima.plus
E-mail: alex@altima.plus
| |
Turkmenistan Alex Filonenko |
| https://carlex-ag.com/web/TM/ |
|
Alex Filonenko
Director, Carlex Export AG, Ukraine, MBA
Tel: +380 44 494 30 15
Mob.: +380 67 236 50 94
Web: altima.plus
E-mail: alex@altima.plus
| |
Uzbekistan Alex Filonenko |
| https://carlex-ag.com/UZ |
|
Alex Filonenko
Director, Carlex Export AG, Ukraine, MBA
Tel: +380 44 494 30 15
Mob.: +380 67 236 50 94
Web: altima.plus
E-mail: alex@altima.plus
CARLEX EXPORT AG works in your country